缘由

超微bmc里面的默认低ct的阈值有点高。如果你的静音风扇(例如猫扇),转速低了,就会强制触发全速,过会降下来,再依次反复。

操作-通过ipmitool更改风扇转速检测阈值

  1. 准备一台电脑,以我的macbook为例。
  2. 在你准备的电脑上安装ipmitool。brew install ipmitool
  3. 使用ipmi命令来降低转速:
#我bmc的ip地址为192.168.50.132为例。所有风扇都配置一遍。
ipmitool -H 192.168.50.132 -U ADMIN -P ADMINPASSWORD sensor thresh FAN1 lower 0 100 125
ipmitool -H 192.168.50.132 -U ADMIN -P ADMINPASSWORD sensor thresh FAN2 lower 0 100 125
ipmitool -H 192.168.50.132 -U ADMIN -P ADMINPASSWORD sensor thresh FAN3 lower 0 100 125
ipmitool -H 192.168.50.132 -U ADMIN -P ADMINPASSWORD sensor thresh FAN4 lower 0 100 125
ipmitool -H 192.168.50.132 -U ADMIN -P ADMINPASSWORD sensor thresh FAN5 lower 0 100 125
ipmitool -H 192.168.50.132 -U ADMIN -P ADMINPASSWORD sensor thresh FANA lower 0 100 125
ipmitool -H 192.168.50.132 -U ADMIN -P ADMINPASSWORD sensor thresh FANB lower 0 100 125

得到反馈:

Locating sensor record 'FAN1'...
Setting sensor "FAN1" Lower Non-Recoverable threshold to 0.000
Setting sensor "FAN1" Lower Critical threshold to 100.000
Setting sensor "FAN1" Lower Non-Critical threshold to 125.000

修改后,进入你的bmc控制台查看你的风扇“低CT”值,是不是降低了?降低了就是成功了。